- Error
Submersible Level Indicator L11
Level gauge L 11 is used for the measuring of the liquid level in opened and pressure tanks. This level gauge makes possible to measure also flicking and whirling levels, aggressive, toxic and flammable materials. The position of a float with magnet is by means of the magnetic field medium transferred to the sensor located in a water pipe. The level indicator can be equipped with the monostable contact (KM) or bistable one (SP1, SP2) to follow one or also some few levels up, or it can be equipped with the SP4 sensor to follow a level continuously and to make possible current outlet.
Benefits of the level indicator L11:
- Simple and rugged design.
- Pressure – resistant and gasproof separating of the indicator and measuring part.
- Suitable for difficult service conditions and for contrary conditions rounds the equipment.
- It measures liquids and liquefied gases with the density more than 400 kg m-3 reliably.
- It bears up against pressure up to 4 MPa, and more by request of Customer.
Parameters

|
Medium |
Liquids, liquid boundary |
|
Max. measurement range |
16 m |
|
Error in electrical output |
± 2,5 mm |
|
Working conditions |
|
|
Working position |
Vertical |
|
Attachment |
Flange |
|
Kind of material |
Stainless, PP, PVC |
|
Local indication |
Evaluation equipment VZI211R with converter to the panel - display of the level, volume and quantity |
|
Electrical outputs |
Output 0/4 – 20 mA |
|
Use in explosive environment |
Yes |
|
Use |
Level indication in pressure and pressureless receivers and tanks |
Downloads - Level meter L11
| File name | Size | Date |
|---|---|---|
| bytes | 1970-01-01 |